The problem is inrush, not running load
Look at the data plate on your outdoor unit and you will see two very different current figures. One is what the compressor draws while running. The other, much larger, is what it draws in the instant it starts against a stopped rotor.
Your utility service absorbs that surge because it is enormous compared to your house. A generator is not. It sees the surge, voltage sags, and the generator either stalls or drops the load. This is the most common reason people discover during a hurricane that their generator will not run their air conditioner.
What the EasyStart does about it
The Micro-Air EasyStart is a soft start module wired into the compressor circuit inside the outdoor unit. Instead of applying full voltage instantly, it ramps the compressor up over a controlled period, which sharply reduces the peak current drawn at start up.
It learns the specific compressor it is attached to over the first several start cycles and tunes its ramp accordingly. After that it works in the background and you never touch it. We install these and have written about them, because in a city that loses power to storms this is one of the few upgrades that changes what your house can do during an outage.
The generator conversation people get wrong
A soft starter reduces the starting surge. It does not reduce what the air conditioner needs to keep running. If your generator cannot carry the running load of the compressor plus the indoor blower plus everything else you have switched on, a soft starter will not rescue it.
So the honest sequence is: read the data plate, add up the running load you intend to support during an outage, then work out whether the surge is the binding constraint. Frequently it is, and a soft starter is the inexpensive fix. Sometimes the generator is simply too small. We will read the plate with you before anybody buys anything.
What a soft starter will not do
It will not make your air conditioner colder or more powerful. It will not meaningfully lower your monthly bill, because running consumption is unchanged. It will not repair a failing compressor, and easing the start can mask that symptom for a while.
It is also unnecessary on some systems. A variable speed inverter compressor already ramps up gradually by design, so a soft start module has nothing to add. If that is what you have, we will tell you to keep your money.
Good reasons to add a soft starter
- You want AC during an outageA generator that stalls when the compressor kicks on is the classic case.
- Lights dim on every startA visible voltage sag through the house each time the compressor starts.
- Nuisance trips at start upThe breaker holds while running but trips on the surge, with no other fault found.
- An RV or a limited supplyShore power or any circuit that cannot absorb a full locked rotor surge.
- You are sizing a standby generatorCutting inrush can change which generator is adequate for your house.