Design comes before metal
We start with a room by room load calculation. Square footage rules of thumb do not account for orientation, window area and type, shading, ceiling height, insulation levels, or how many people use a room. Two rooms of the same size on opposite sides of a Houston house have very different loads at four in the afternoon.
The static pressure budget
Every duct system has a pressure budget set by the blower. Every fitting, turn, length of flex, register, grille, filter, and coil spends part of it. Design is spending that budget deliberately instead of discovering later that it ran out.
Fabrication
Billy Wagner came up through commercial work and spent time on a government contract overseas doing air conditioning, plumbing, electrical, and custom fabrication. That background shows up here. When a plenum, transition, or drop box needs to be made to fit a specific space, we make it rather than forcing a stock part where it does not belong.
Sealed sheet metal trunks with properly built takeoffs, mastic at every joint, and flex used only for the last run to the boot: that is the arrangement that holds its performance. Air Star Now is licensed in Texas under TACLA36229C.
Where the equipment sits, and how it drains
In most Houston homes the air handler is in the attic. That dictates a platform holding the unit level and accessible, a secondary drain pan, a properly trapped primary condensate drain, a secondary drain line, and a float switch that shuts the system down before water reaches your ceiling.
A stopped or dried out condensate trap is one of the most common and most preventable service calls we run. Building the drain correctly on day one prevents it. Service clearance matters too: if a technician cannot reach the coil or blower in five years, your maintenance suffers for the life of the system.
Commissioning
Once the system runs we measure it: total external static pressure, airflow at each register against the design number, temperature split across the coil, refrigerant charge, and indoor humidity after it has pulled the house down.
What a proper duct design includes
- Room by room loadAirflow derived from each room's actual heat gain, not from floor area.
- Equipment selectionCapacity matched to the load, including the moisture load our climate adds.
- Trunk and branch sizingDuct sizes chosen against a friction rate the blower can support.
- Return capacityA return path sized so the blower is not starved with doors closed.
- Condensate designTrapped primary drain, secondary pan and line, and a float switch.
- Service accessClearance to reach the coil, blower, filter, and drain later.